Normal view MARC view ISBD view

UV spectrophotometric determination of rupatadine fumarate in bulk and tablet dosage form by using single point standardization method

By: Basha, S. Shakir.
Contributor(s): Manikanta, S.
Publisher: Bhopal Innovare Academic Sciences Pvt Ltd 2019Edition: Vol. 11 (07).Description: 120-124p.Subject(s): PHARMACEUTICSOnline resources: Click here In: International journal of pharmacy and pharmaceutical scienceSummary: Objective: To develop and validate a simple, selective, precise and accurate method for the estimation of rupatadine fumarate in bulk and tablet dosage form by using the single point standardization method as per international conference on harmonization (ICH) guidelines. Methods: In this proposed method, the absorbance of a standard solution of known concentration and a sample solution was measured. From this, the concentration of the unknown can be calculated. Results: Rupatadine fumarate showed maximum absorbance at 246 nm with methanol. Linearity was checked in different concentrations. The calibration curve was obtained in the range of 2-10 µg/ml. The slope, intercept and correlation coefficient (R2) values of Rupatadine fumarate were found to be 0.047, 0.0034 and 0.9995 respectively. Intra-day and inter-day precision studies were carried out and there % RSD values were found within limits i.e. less than 2%. The recovery studies were carried out by adding a known amount of standard drug to preanalysed formulation and % Recovery was found to be within 99.7-101.6%. LOD and LOQ of Rupatadine fumarate were found to be 0.1 µg/ml and 0.3 µg/ml respectively. Robustness studies were performed at different wavelengths and the % RSD was found within the limits i.e. less than 2 %. Conclusion: The developed single point standardization method for the estimation of Rupatadine fumarate was found to be simple, precise, accurate, reproducible and cost-effective. Statistical analysis of the developed method confirms that the proposed method is an appropriate and it can be useful for the routine analysis. The proposed method gives the basic idea to the researcher who is working in the area like product development. Keywords: Rupatadine fumarate, Standardization, Robustness, Reproducible
Tags from this library: No tags from this library for this title. Log in to add tags.
    average rating: 0.0 (0 votes)
Item type Current location Call number Status Date due Barcode Item holds
Articles Abstract Database Articles Abstract Database School of Pharmacy
Archieval Section
Not for loan 2020189
Total holds: 0

Objective: To develop and validate a simple, selective, precise and accurate method for the estimation of rupatadine fumarate in bulk and tablet dosage form by using the single point standardization method as per international conference on harmonization (ICH) guidelines.

Methods: In this proposed method, the absorbance of a standard solution of known concentration and a sample solution was measured. From this, the concentration of the unknown can be calculated.

Results: Rupatadine fumarate showed maximum absorbance at 246 nm with methanol. Linearity was checked in different concentrations. The calibration curve was obtained in the range of 2-10 µg/ml. The slope, intercept and correlation coefficient (R2) values of Rupatadine fumarate were found to be 0.047, 0.0034 and 0.9995 respectively. Intra-day and inter-day precision studies were carried out and there % RSD values were found within limits i.e. less than 2%. The recovery studies were carried out by adding a known amount of standard drug to preanalysed formulation and % Recovery was found to be within 99.7-101.6%. LOD and LOQ of Rupatadine fumarate were found to be 0.1 µg/ml and 0.3 µg/ml respectively. Robustness studies were performed at different wavelengths and the % RSD was found within the limits i.e. less than 2 %.

Conclusion: The developed single point standardization method for the estimation of Rupatadine fumarate was found to be simple, precise, accurate, reproducible and cost-effective. Statistical analysis of the developed method confirms that the proposed method is an appropriate and it can be useful for the routine analysis. The proposed method gives the basic idea to the researcher who is working in the area like product development.
Keywords: Rupatadine fumarate, Standardization, Robustness, Reproducible

There are no comments for this item.

Log in to your account to post a comment.

Click on an image to view it in the image viewer

Unique Visitors hit counter Total Page Views free counter
Implemented and Maintained by AIKTC-KRRC (Central Library).
For any Suggestions/Query Contact to library or Email: librarian@aiktc.ac.in | Ph:+91 22 27481247
Website/OPAC best viewed in Mozilla Browser in 1366X768 Resolution.

Powered by Koha